b Links Contact About Home Products & Services
 
 
   

Financial & Commercial Alarm Security:

Learn about: MAXSYS | 864 system | Fire






Communications...an extensive range of options!

  • Cellular
  • Digital
  • Long Range Radio
  • Event Initiated Paging

LOADED WITH FEATURES
"RIGHT OUT OF THE BOX"


·

4 or 8 system partitions

·

1,000 user codes

·

3,000 event buffer

·

30 programmable zone types

·

59 programmable output options

·

local and remote upload/download

·

99 date schedules

·

50 arm/ disarm schedules

·

99 open/ close suppression schedules

·

two-year holiday scheduling

·

automatic daylight savings adjustment

·

add up to 16 LCD keypads

·

add up to 64 programmable relays

·

add up to 144 low power outputs

·

add point/graphic annunciation

·

UL & ULC listed for :
·  residential
·  commercial applications

·

And much more…

The PC4020 is easily expanded by adding input/output and functional modules onto the 4-wire communications bus (Combus).

  • Combus… up to four runs of 1,000 feet (330m), can be T-tapped and is supervised for low voltage and module communication.
  • up to 16 LCD keypads… 32 character display

 

-

keypads can be 'partition' or 'global' operation

 

-

complete system programming via keypads

 

-

Ready, Armed, and Trouble indicators – LCD4501

 

-

5 programmable function keys – LCD4501

 

-

27 function key options

 

-

Trouble and Armed indicators – LCD4500

 

-

piezo buzzer for audible feedback and trouble

 

-

4 keypad-activated alarms – Panic, Emergency, Fire, Duress

 

 

  • up to 128 hardwired zones… using PC4108A/ PC4116 eight and sixteen zone expansion modules.
  • up to 64 wireless zones… using the PC4164RS wireless receiver and DSC wireless sensors and control devices.
  • up to 112 addressable zones… using the main panel PGM outputs as addressable loops and DSC addressable sensors. Hardwired, Wireless and Addressable zones may be mixed on the system up to the total system capacity of 128 zones.
  • up to 144 low current outputs… using PC4216 modules – 16 outputs per module – 9 modules per system.
  • up to 64 relay outputs… using PC4204 quad relay/ power supply modules – up to 16 modules/system – the PC4204 also provides up to 16 amps of auxiliary power and can be used to repower the Combus.
  • point/ graphic annunciation… using PC4632/PC4664 remote annunciators for system, partition and zone annunciation
  • up to 32 access-controlled doors… using up to 16 PC4820 two reader access control modules with standalone capability.
  • X-10 automation… using the Escort4580 module – controls up to thirty two X-10 devices and provides voice-assisted system status and control from any touchtone telephone.
  • system printer or DVACS communicator… using the PC4400 printer interface module.
  • backup alarm communication using :
  • All of the features, functions, and expansion capabilities of the PC4020 control panel are included in the PC4020CF versions.

·  UP TO 128 FULLY PROGRAMMABLE ZONES
- 16 ZONES ON MAIN CONTROL PANEL (zones can be NC with no EOLR, NO/NC with single EOLR or NC with double EOLR.
- HARDWIRE AND WIRELESS ZONE EXPANSION
- ALL ZONES PROGRAMMABLE AS BURGLARY OR FIRE
- ASSIGN ZONES TO ONE OR MULTIPLE PARTITIONS
- 30 PROGRAMMABLE ZONE TYPE

·  8 PARTITIONS  ( 9 accounts)
- ALL FEATURES PROGRAMMABLE BY PARTITION
- SEPARATE SIREN OUTPUT PROGRAMMABLE FOR EACH PARTITION
- 128 - 4 OR 6 ACCESS CODES ASSIGNABLE TO ONE OR SEVERAL PARTITIONS

·  3000 EVENT BUFFER
-  3000 EVENT BUFFER CAN BE : PRINTED ON SITE OR DLS SOFTWARE
-  2800 VIEWED FROM KEYPAD 

·  ALARM OUTPUT
- BELL OUTPUT - 700 mA @ 12VDC
- ADDITIONAL SIREN OUTPUT HIGH CURRENT USING PC-4204 (4 OUTPUT PER MODULE) MAX. 16 MODULES PER SYSTEM
- ADDITIONAL 144 LOW CURRENT OUTPUT WITH PC-4216

·  SUPERVISED DIGITAL ALARM COMMUNICATOR with 4 formats :
- 20bps, 1400/ 2300Hz handshake
- Contact ID
- SIA with auto-reporting codes

·  MULTIPLE COMMUNICATION CAPABILITIES
-
Built in digital dialer
-optional module for DVAC
-Optional Cellular Communication

·  COMPREHENSIVE  SCHEDULING
-
99 date schedules
-50 arm/disarm schedules
-16 automation schedules
-4 two year holiday schedules
-99 open/close suppression schedules
-50 addressable smoke detector test schedule

 

Add Ons

Seismic detector

Safes and other deposit boxes for valuables at risk from burglary are reliably monitored with a seismic detector. Even the smallest seismic vibrations are detected by a crystal microphone. The (software-based) high-tech noise analysis can be adapted to the protected object and to typical burglary noises (drilling, blasting, oxygen lances). This guarantees high response reliability over a wide area of application - from traditional safe design to automatic cash and ticket dispensers.

 

Rate of rise heat detector


The rate of rise heat detector is for use in areas where a optical smoke would be likely to give unwanted alarms (bathrooms, kitchens, unheated rooms etc).

The rate of rise is a two part detector if the temperature at the detector increases at rate greater then 3 degrees centigrade a minute then the detector will trigger into alarm. But if the temperature increases at a slower rate but reaches 60 degrees centigrade the detector will also trigger into alarm.


Ionization smoke detector

Ionization chamber smoke detectors contain a small amount of radioactive material encapsulated in a metal chamber. They take advantage of the ions created by ionizing radiation to develop a low, but steady electrical current.  Smoke particles entering the chamber disrupt the current and trigger the detector's alarm.  Ionization chamber detectors react more quickly to fast flaming fires that give off little smoke.

 

Skyroute

What is Skyroute ™ ?

SG Wireless Communications is pleased to provide to the security industry a new method of communication for the transmission of event conditions. Unlike traditional methods of communication that rely on a direct connection, such as regular phone lines, Skyroute takes advantage of a breakthrough technology called Cellemetry Data Service.

Cellemetry enables alarm equipment to be remotely monitored in a secure, cost-effective manner by using the existing cellular network control channels. Skyroute therefore offers improved security, does not utilize phone lines and is not subject to sabotage or accidental phone outages when lines are down. Combined with landline communication, Skyroute provides dual path communication to the central station to ensure that "the alarm always gets through" in case of emergency.

What is Cellemetry?

Cellemetry is a breakthrough technology that transmits short messages via the control channels of the cellular network. The analog cellular network (AMPS) is divided into 790 voice channels and 42 control channels. The control channels are used to initiate cellular telephone calls. Once the call is initiated, the cellular system directs the telephone call to a voice channel.

The control channels are more robust than the voice channels for several reasons. First, the control channels are digital, unlike the voice channels which are analog. This can be compared to the superior quality of compact disc versus vinyl records. The control channels also operate at higher transmission power than the voice channels, giving better coverage. Finally, the cost of using the control channels is far less than the regular voice channels. By using the cellular network, Cellemetry takes advantage of a proven technology used by millions of cellular users and available virtually everywhere. By far, the analog cellular network is the biggest radio network in the world and there are already 200,000,000 packets of data transmitted over the control channels every day in North America. This represents an average of only 10% of the maximum control channel capacity.

How does Cellemetry work?

The Cellemetry Service operates in the same manner in which roaming telephones operate in the cellular system. A roaming telephone is defined as a cellular telephone operating in any system other than its home system. When a cellular telephone is turned on outside of its home system it sends its Mobile Identification Number (MIN) and its Electronic Serial Number (ESN) to the cellular system via one of the control channels. Based on the cellular phone number, the local cellular switch is able to communicate with the "Home System" of the roaming telephone. It uses the SS7 network which interconnects all cellular switches in North America to confirm the user is allowed to use the system and the phone calling features that are available to that customer. The Cellemetry radio, like a roaming cellular telephone, sends an ESN and MIN number over the SS7 network, but the MINs are specifically assigned so the MIN and ESN are routed to a Cellemetry Service Gateway that is also connected to the SS7 cellular network. The MIN serves to identify the Cellemetry radio and the ESN is the data field that contains the Skyroute alarm message.

How the signal travels to the Central Station

When an alarm is triggered at the monitored site, a signal is sent via Skyroute to the cellular network and then, via the NA intra-cellular network to the "Cellemetry Gateway" from there, the signal is sent to Connect 24 Data Communications. The Clearing House then forwards the alarm to the appropriate central station for dispatch. Once the alarm has been successfully received at the central station, Connect 24 returns a confirmation to the Skyroute unit via the cellular network. Please note that one alarm signal is sent per transmission. Multiple alarms will generate multiple transmissions over the cellular network.

 

Who is Connect 24 Data Communications?

Connect 24, a member of the DSC Group of Companies, is the service provider created specifically to offer the Skyroute service to the security industry. Founded in 1997, Connect 24 has put in place a secure facility that meets the highest standards of UL ratings for the routing of critical condition signals. Connect 24 also offers a reliable and fully automated system for the activation of Skyroute Transceivers. This service is available 24 hours a day, 365 days a year for the activation of your Skyroute Cellemetry Transmitter. As a routing center, Connect 24 receives signals from the cellular network and re-routes them to the central station. Upon receiving a confirmation of reception from the central station, it returns a signal back to the Skyroute transceiver over the cellular network. In doing so, the Skyroute transceiver receives a confirmation of delivery of an alarm condition or an opening/closing to the Central Station, eliminating the chance of signal loss.



864 with LCD keypad

Features of the 864 security system:

  • 64 zones – 8 on-board zones, expandable to 64 hardwired/wireless
  • 8 Partitions
  • 256 event buffer, viewable through the keypad
  • Built-in digital communicator
  • Telephone interface – turns any phone into a system keypad
  • 4 on-board relays, expandable to 14 relays
  • Supports up to 15 intercom stations.
  • 48 system user codes
  • User scheduling to automatically activate X-10 devices to trigger lights and other appliances
  • Chime by zone

864 Includes:

  • Wired LCD keypad

  • Metal enclosure with lock

  • Set 2K End-of-Line Resistors

  • Set Installation, Programming & End User Manuals

  • Access to our On-line technical support

DSC’s security systems are much more than reliable and easy-to-use burglar alarms.  The Power832 and Power864 security systems allow you to integrate a multitude of convenience and life safety features, affording you the peace of mind you’ll experience for years to come.   Home Automation – Imagine a security system that controls your home appliances.  With these systems you can adjust your heating, control the lights, open your garage, unlock your gates, and turn on your sprinkler system… all with just a simple phone call.  You can even program your system to turn on the lights in the event of a burglar or fire alarm.  Wireless Control - DSC’s wireless security technology lets you add control from near or far, easy to install and maintain.  Remote Telephone Access – While on vacation, or traveling on business, there’s no need to worry about your home. With these DSC panels, you can check on your system from anywhere in the world.  15 Station Intercom – DSC’s integrated intercom system allows you to listen to the baby sleeping in the nursery and communicate with the children in the playroom while you work in your 2nd floor office.  As you can see, DSC security systems keep you safe and so much more.




Commercial Alarm Security:






Communications...an extensive range of options!

  • Cellular
  • Digital
  • Long Range Radio
  • Event Initiated Paging

The PC4020CF is the UL listed commercial fire version of the PC4020 security control panel. As such, the PC4020CF has the same system expandability and features as the PC4020 plus added features and expandability for commercial fire applications as described herein.
with UL864 Commercial Fire listings, plus all the features of MAXSYS security systems!

Take a MAXSYS security system with fire savvy software and specially engineered fire application hardware, and not only do you have a great security system, you also have a powerful fire alarm system.

Special Software Features for Fire

Alarm Auto-Scroll…displays fire alarms and selected fire troubles at two second intervals on all system keypads.

Fire Drill…user-initiated for easy evacuation drills.

Fire Inspector's Test…simplifies system verification testing.

Auto-Verify…programmable by zone for 2-wire, 4-wire and addressable smoke detector zones.

Waterflow Delay…programmable timer for waterflow zones.

Fire Silence Inhibit…prevent manual signal silence for a programmable time period.

Synchronized Temporal Pattern…automatic synchronized audible alarm notification for zones programmed with the temporal pattern.

Fire Zone Annunciation.

Fire specific information at a glance!

Especially designed for fire systems, the PC4612 complements the use of standard PC4632/ PC4664 annunciators, which may be used on the same fire system, by adding specific annunciation for fire alarm zones, fire supervisory zones, and fire troubles.

 

 

Addressable Smoke detectors.

Use addressable loops to add up to 56 DSC UL/ ULC listed addressable smoke detectors on PC4010CF systems and 112 on PC4020CF systems to meet the needs of large applications efficiently and economically.