Power 832 Security System It used to be that a burglar alarm was all you needed to feel safe. Well, times have changed. And so have your security options. In keeping with new times and new technologies. Introducing Power 832...from DSC. A security system that is more than a burglar alarm. easy-to-use, affordable system that will offer you peace of mind.
Home Automation Imagine a security system that will control your appliance. With this system you can adjust your heating, control the light, open your garage door, unlock your gates, and turn on your sprinkler system...all with just a simple phone call. With the Power 832, you can even program your system to turn on the lights in the event of a burglar or fire alarm. More great ways to stay safe from DSC.
Paging Can't be home to greet the kids after school? Would like to track the number of hours your housekeeper spends in you home? Have peace of mind knowing that your system will page you the minute your kids walk through the door. Or when your housekeeper leaves for the day. Power 832 offers different codes for different needs to suit your own personal lifestyle.
Remote Telephone Access When your on vacation or on business travel, there's no need to worry about your home. with Power 832, you can check on your system from anywhere in the world. It's worldwide telephone assess, you instantly know if your system is armed or if there have been any alarms. Talk about peace of mind.
7 Station Intercom Power 832 offers so many new and exciting way to keep you and your family safe. Our 7 station intercom allows you to listen to the baby sleeping in the nursery, and communicate with your children in the playroom while you work in your 2nd floor office. Talk to people at your door without having to open it. All this security....and hands-free too!
Smoke Alarm DSC's smoke alarm detector provides superior sensitivity to all types of smoke and in linked to alarm the Power 832 in case of smoke detection.
832 DETAILS
support up to 32 zones using any combination of up to :
- |
8 hardwire zones on main panel |
- |
4 general purpose hardwire zones and 2 waterflow hardwire zones using PC5700 fire module (in Canada only) |
- |
24 hardwire zones using PC5108 eight zone expander modules |
- |
8 keypad zones |
- |
Or up to 32 wireless zones using PC5132 wireless reciever module |
zone programming
- |
all zones programmable as burglary or fire |
- |
zone options include : Normally Closed loop, Single End of Line (EOL) resistor, and Double EOL resistor *
* keypad zones cannot be programmed as fire zones and cannot support Double EOL resistor supervision |
- |
27 programmable zone types, 8 programmable zone options |
audible alarm output
- |
Supervised bell output - 700 mA @ 12VDC, PTC protected, current limited at 3 A |
- |
Steady, pulsed, temporal pattern, or strobe fire output |
- |
Additional supervised siren output is available using PC5204 power supply module |
programmable voltage outputs
- |
1 high current 300mA PGM… can also be used for 2 wire smoke with a maximum of 20 detectors at 15mA per detector |
- |
1 low current 50mA PGM |
- |
8 additional low current PGM outputs using PC5208 module |
- |
4 additional high current PGM outputs using PC5204 module |
- |
24 programmable options |
Remote upload/download capability
- |
View status and trouble conditions, and system 128 event buffer |
- |
Remote access can be controlled by owner to prevent unauthorized access to system |
power supply
- |
550mA @ 12.5VDC auxiliary power (400mA for UL applications) |
- |
Positive temperature coefficient (PTC) protected battery, AUX, and Bell output |
- |
Electronic protection of KEYBUS |
- |
Supervision of AC power loss, low battery, auxiliary power failure |
- |
Internal clock locked to AC power frequency |
EEPROM memory
- |
will not lose programming or system status on complete AC and battery failure |
Digital Communicator
- |
Supports all major formats including SIA & Contact ID |
- |
Supports cellular backup communications |
- |
3 phone numbers (3rd backs up primary) |
- |
2 account numbers |
- |
DTMF or pulse dialing |
- |
DPDT line seizure |
- |
Anti-jam feature |
- |
Split reporting of selected events to each telephone number |
- |
Event initiated personal paging |
Other Facts
Battery required : 12V, 4 Ah, rechargeable sealed lead aci
transformer required : 16.5VAC, 40VA2 system partitions… 2 account numberseach partition acts as a separate alarm system with any number of zones, user codes, keypads and individually programmable features
38 - 4 or 6 digit access code
| - |
32 user codes, 1 system master code, 2 partition master codes, 2 duress codes, and 1 maintenance code |
- automatic arming by partition
| - |
Each partition may be programmed to auto-arm at its own time each day |
| - |
Panel can be programmed to lockout keypad if a series of incorrect access code entries are made |
- 'quick arm' and 'quick exit'
| - |
Allows users to arm and exit easily |
- 'stay/away' zones and 'stay' arming
| - |
Security of perimeter arming while premise is occupied |
| - |
Programmable by zone |
| - |
Monitor a door by having the keypad beeping when the door is opened and again when the door is closed |
128 event buffer
-all events automatically stored with time and date stamp to buffer
-
events can be printed on-site using the PC5400 serial printer interface module, viewed through an LCD Keypad, or viewed and printed via PC using DLS software
 |
DSC Products
Power 632 (part of the DSC series)

|
6 hardwire zones on main control panel
-
keypad input zones (1 per keypad)
-
32 wireless zones using PC5132 wireless receiver
-
6 hardwired keypads available…
- |
PC1555RKZ eight zone LED keypad with zone input |
- |
PC5508Z eight zone LED keypad with zone input |
- |
PC5516Z sixteen zone LED keypad with zone input |
- |
PC5532Z thirty two zone LED keypad with zone input |
- |
LCD5500Z alphanumeric keypad with zone input |
- |
PC5501-403 Keypad with an integrateded wireless receiver |
-
Added wireless control

-
PGM1 and PGM2 with 24 programmable options
-
supports all major formats including SIA and Contact ID
-
Cellular back-up communication
-
DVACS using PC5400DV-SG in place of PC5400 printer module
-
Event-initiated personal paging
-
3 phone numbers (3rd backs up primary number)
-
2 account numbers
TOP